Until now the I2C PD was basically ignoring the very first sample, and
using that as the initial 'oldscl'/'oldsda' value.
However, if your logic analyzers trigger on, say, SDA=low that will
result in a file where the first sample is really important since it
is the one which the PD will need to know that there's a falling edge
on SDA.
Thus, assume both SCL and SDA are high/1 when the PD starts. This is
a good assumption since both pins have pullups on them in practice
and are thus high/1 when the bus is idle.
Later on we might want to have config options to let the PD assume
other states of SDA/SCL initially.
|
|
|
|
|
|
The Python module name is determined by the directory name (e.g. dcf77),
the *.py file names in that directory don't matter and can be kept
consistent.
|
|
Ignore/skip identical samples in most (low-level) PDs, as we're usually
(but not necessarily always) only interested in pin changes.
This yields a significant performance improvement for the PDs.
The mechanism was already used in the 'i2s', 'jtag', and 'lpc' PDs, but not
yet in all supported low-level decoders. The following PDs now also use
this mechanism: 'dcf77', 'i2c', 'spi', 'uart', and 'usb_signalling'.
Thanks Lars-Peter Clausen <lars@metafoo.de> for bringing this to our
attention.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- List all API methods and metadata variables in all PDs to make things
easier and more consistent for new PD writers.
- Fix probe assignment in a few PDs.
- Raise exceptions upon invalid states of the PD state machines (bug).
|
|