diff options
author | Uwe Hermann <uwe@hermann-uwe.de> | 2019-06-30 23:39:18 +0200 |
---|---|---|
committer | Uwe Hermann <uwe@hermann-uwe.de> | 2019-06-30 23:39:18 +0200 |
commit | 07d42ff5ae23e76d6a0caa241542414e99ce80a4 (patch) | |
tree | d0307bd1ea972f46bbd0de7d1583ac0f6f71cebc /decoder/test/modbus/test.conf | |
parent | fc163ecc2fba91ed7ae516af004e0973d943d6b1 (diff) | |
download | sigrok-test-07d42ff5ae23e76d6a0caa241542414e99ce80a4.tar.gz sigrok-test-07d42ff5ae23e76d6a0caa241542414e99ce80a4.zip |
modbus: Add a few flowmeter test-cases.
Diffstat (limited to 'decoder/test/modbus/test.conf')
-rw-r--r-- | decoder/test/modbus/test.conf | 35 |
1 files changed, 35 insertions, 0 deletions
diff --git a/decoder/test/modbus/test.conf b/decoder/test/modbus/test.conf index 2dfda15..3949895 100644 --- a/decoder/test/modbus/test.conf +++ b/decoder/test/modbus/test.conf @@ -4,3 +4,38 @@ test brainchild_io_16do stack uart modbus input uart/modbus_rtu/brainchild_io_16do/brainchild-io-16do.sr output modbus annotation match brainchild_io_16do.output + +test flowmeter_graph_tool + protocol-decoder uart channel rx=2 option baudrate=9600 + protocol-decoder modbus option scchannel=RX option cschannel=RX + stack uart modbus + input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr + output modbus annotation match flowmeter_graph_tool.output + +test flowmeter_target0_val0 + protocol-decoder uart channel rx=2 option baudrate=9600 + protocol-decoder modbus option scchannel=RX option cschannel=RX + stack uart modbus + input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr + output modbus annotation match flowmeter_graph_tool.output + +test flowmeter_target_0liter_per_min + protocol-decoder uart channel rx=2 option baudrate=9600 + protocol-decoder modbus option scchannel=RX option cschannel=RX + stack uart modbus + input uart/modbus_rtu/flowmeter/flowmeter_target_0liter_per_min.sr + output modbus annotation match flowmeter_target_0liter_per_min.output + +test flowmeter_target_15liter_per_min + protocol-decoder uart channel rx=2 option baudrate=9600 + protocol-decoder modbus option scchannel=RX option cschannel=RX + stack uart modbus + input uart/modbus_rtu/flowmeter/flowmeter_target_15liter_per_min.sr + output modbus annotation match flowmeter_target_15liter_per_min.output + +test flowmeter_target_20liter_per_min + protocol-decoder uart channel rx=2 option baudrate=9600 + protocol-decoder modbus option scchannel=RX option cschannel=RX + stack uart modbus + input uart/modbus_rtu/flowmeter/flowmeter_target_20liter_per_min.sr + output modbus annotation match flowmeter_target_20liter_per_min.output |