modbus: Make C->S and S->C configurable, add framegap option.
Change client->server and server->client to be separately configurable, allowing decoding at both the server (where client->server is RX and server->client is TX) and client (where client->server is TX and server->client is RX) ends of the link. It also allows monitoring of the bus on a single channel (where client->server and server->client are both RX (or TX)). When I tried to decode a bus capture, I found that when the transmitter was turned off it generated a false start bit, which in turn resulted in a false trailing byte from the UART decoder. This narrowed the inter-frame gap to the point where the Modbus decoder failed to recognise a new frame. The result was only the first frame of the capture decoded - all the rest of the frames failed to decode. I had to reduce the frame gap to allow subsequent frames to decode, and so made it a configurable option that defaults to the existing gap. Lastly, I fixed a call to puti() that incorrectly included the annotation prefix.