summaryrefslogtreecommitdiff
path: root/decoder/test/modbus/brainchild_io_16do.output
blob: 6c651d8744e34f342a42ac8e49000f6ffe40ff22 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
31179-31597 modbus: cs-server-id: "Slave ID: 1"
31756-32174 modbus: cs-function: "Function 1: Read Coils"
32333-33329 modbus: cs-address: "Start at address 0x3 / 10004"
33488-34484 modbus: cs-length: "Read 1 units of data"
34643-35638 modbus: cs-crc: "CRC correct"
37901-38319 modbus: sc-server-id: "Slave ID: 1"
38475-38893 modbus: sc-function: "Function 1: Read Coils"
39049-39467 modbus: sc-length: "Byte count: 1"
39622-40040 modbus: sc-data: "00000001"
40196-41188 modbus: sc-crc: "CRC correct"
44485-44903 modbus: cs-server-id: "Slave ID: 1"
45062-45480 modbus: cs-function: "Function 2: Read Discrete Inputs"
45639-46634 modbus: cs-address: "Start at address 0x0 / 20001"
46794-47789 modbus: cs-length: "Read 1 units of data"
47949-48944 modbus: cs-crc: "CRC correct"
51201-51619 modbus: sc-server-id: "Slave ID: 1"
51775-52193 modbus: sc-function: "Function 2: Read Discrete Inputs"
52349-52767 modbus: sc-length: "Byte count: 1"
52923-53341 modbus: sc-data: "00000000"
53496-54488 modbus: sc-crc: "CRC correct"
58485-58903 modbus: cs-server-id: "Slave ID: 1"
59062-59480 modbus: cs-function: "Function 3: Read Holding Registers"
59639-60635 modbus: cs-address: "Start at address 0x63 / 30100"
60794-61790 modbus: cs-length: "Read 1 units of data"
61949-62944 modbus: cs-crc: "CRC correct"
65180-65598 modbus: sc-server-id: "Slave ID: 1"
65753-66171 modbus: sc-function: "Function 3: Read Holding Registers"
66327-66745 modbus: sc-length: "Byte count: 2"
66901-67893 modbus: sc-data: "0x0201 / 513"
68048-69040 modbus: sc-crc: "CRC correct"
72485-72903 modbus: cs-server-id: "Slave ID: 1"
73062-73480 modbus: cs-function: "Function 4: Read Input Registers"
73640-74635 modbus: cs-address: "Start at address 0x78 / 40121"
74795-75790 modbus: cs-length: "Read 1 units of data"
75949-76945 modbus: cs-crc: "CRC correct"
79158-79576 modbus: sc-server-id: "Slave ID: 1"
79732-80150 modbus: sc-function: "Function 4: Read Input Registers"
80306-80724 modbus: sc-length: "Byte count: 2"
80879-81871 modbus: sc-data: "0x4B00 / 19200"
82027-83019 modbus: sc-crc: "CRC correct"
86493-86911 modbus: cs-server-id: "Slave ID: 1"
87071-87489 modbus: cs-function: "Function 5: Write Single Coil"
87648-88643 modbus: cs-address: "Address 0x3 / 10003"
88803-89798 modbus: cs-data: "Coil Value ON"
89957-90953 modbus: cs-crc: "CRC correct"
93189-93607 modbus: sc-server-id: "Slave ID: 1"
93762-94180 modbus: sc-function: "Function 5: Write Single Coil"
94336-95328 modbus: sc-address: "Address 0x3 / 10003"
95484-96475 modbus: sc-data: "Coil Value ON"
96631-97623 modbus: sc-crc: "CRC correct"
101484-101902 modbus: cs-server-id: "Slave ID: 1"
102062-102480 modbus: cs-function: "Function 6: Write Single Register"
102639-103634 modbus: cs-address: "Address 0x1 / 30001"
103794-104789 modbus: cs-data: "Register Value 0x55 / 85"
104949-105944 modbus: cs-crc: "CRC correct"
108158-108576 modbus: sc-server-id: "Slave ID: 1"
108732-109150 modbus: sc-function: "Function 6: Write Single Register"
109305-110297 modbus: sc-address: "Address 0x1 / 30001"
110453-111445 modbus: sc-data: "Register Value 0x55 / 85"
111600-112592 modbus: sc-crc: "CRC correct"
116494-116912 modbus: cs-server-id: "Slave ID: 1"
117071-117489 modbus: cs-function: "Function 15: Write Multiple Coils"
117649-118644 modbus: cs-address: "Start at address 0x2 / 10003"
118803-119799 modbus: cs-length: "Write 1 Coils"
119958-120376 modbus: cs-length: "Byte count: 1"
120535-120953 modbus: cs-data: "Value 0x1"
121113-122108 modbus: cs-crc: "CRC correct"
124379-124797 modbus: sc-server-id: "Slave ID: 1"
124953-125371 modbus: sc-function: "Function 15: Write Multiple Coils"
125527-126518 modbus: sc-address: "Start at address 0x2 / 10003"
126674-127666 modbus: sc-data: "Write 1 Coils"
127822-128813 modbus: sc-crc: "CRC correct"
132488-132906 modbus: cs-server-id: "Slave ID: 1"
133065-133483 modbus: cs-function: "Function 16: Write Multiple Registers"
133642-134638 modbus: cs-address: "Start at address 0x1 / 30002"
134797-135793 modbus: cs-length: "Write 1 Registers"
135952-136370 modbus: cs-length: "Byte count: 2"
136529-136947 modbus: cs-data: "Value 0x0"
137107-137525 modbus: cs-data: "Value 0xAA"
137684-138679 modbus: cs-crc: "CRC correct"
140913-141331 modbus: sc-server-id: "Slave ID: 1"
141487-141905 modbus: sc-function: "Function 16: Write Multiple Registers"
142061-143052 modbus: sc-address: "Start at address 0x1 / 30002"
143208-144200 modbus: sc-data: "Write 1 Registers"
144356-145347 modbus: sc-crc: "CRC correct"
199560-199978 modbus: cs-server-id: "Slave ID: 1"
200137-200555 modbus: cs-function: "Function 1: Read Coils"
200715-201710 modbus: cs-address: "Start at address 0x3 / 10004"
201869-202865 modbus: cs-length: "Read 1 units of data"
203024-204019 modbus: cs-crc: "CRC correct"
206267-206685 modbus: sc-server-id: "Slave ID: 1"
206841-207259 modbus: sc-function: "Function 1: Read Coils"
207415-207833 modbus: sc-length: "Byte count: 1"
207989-208407 modbus: sc-data: "00000001"
208562-209554 modbus: sc-crc: "CRC correct"
213495-213913 modbus: cs-server-id: "Slave ID: 1"
214072-214490 modbus: cs-function: "Function 2: Read Discrete Inputs"
214650-215645 modbus: cs-address: "Start at address 0x0 / 20001"
215804-216800 modbus: cs-length: "Read 1 units of data"
216959-217954 modbus: cs-crc: "CRC correct"
220194-220612 modbus: sc-server-id: "Slave ID: 1"
220767-221185 modbus: sc-function: "Function 2: Read Discrete Inputs"
221341-221759 modbus: sc-length: "Byte count: 1"
221915-222333 modbus: sc-data: "00000000"
222489-223480 modbus: sc-crc: "CRC correct"
227494-227912 modbus: cs-server-id: "Slave ID: 1"
228071-228489 modbus: cs-function: "Function 3: Read Holding Registers"
228649-229644 modbus: cs-address: "Start at address 0x63 / 30100"
229803-230799 modbus: cs-length: "Read 1 units of data"
230958-231954 modbus: cs-crc: "CRC correct"
234172-234590 modbus: sc-server-id: "Slave ID: 1"
234746-235164 modbus: sc-function: "Function 3: Read Holding Registers"
235319-235737 modbus: sc-length: "Byte count: 2"
235893-236885 modbus: sc-data: "0x0201 / 513"
237041-238032 modbus: sc-crc: "CRC correct"
241488-241906 modbus: cs-server-id: "Slave ID: 1"
242065-242483 modbus: cs-function: "Function 4: Read Input Registers"
242642-243638 modbus: cs-address: "Start at address 0x78 / 40121"
243797-244792 modbus: cs-length: "Read 1 units of data"
244952-245947 modbus: cs-crc: "CRC correct"
248202-248620 modbus: sc-server-id: "Slave ID: 1"
248776-249194 modbus: sc-function: "Function 4: Read Input Registers"
249350-249768 modbus: sc-length: "Byte count: 2"
249924-250915 modbus: sc-data: "0x4B00 / 19200"
251071-252063 modbus: sc-crc: "CRC correct"
255496-255914 modbus: cs-server-id: "Slave ID: 1"
256073-256491 modbus: cs-function: "Function 5: Write Single Coil"
256651-257646 modbus: cs-address: "Address 0x3 / 10003"
257805-258801 modbus: cs-data: "Coil Value ON"
258960-259955 modbus: cs-crc: "CRC correct"
262181-262599 modbus: sc-server-id: "Slave ID: 1"
262755-263173 modbus: sc-function: "Function 5: Write Single Coil"
263328-264320 modbus: sc-address: "Address 0x3 / 10003"
264476-265468 modbus: sc-data: "Coil Value ON"
265623-266615 modbus: sc-crc: "CRC correct"
270495-270913 modbus: cs-server-id: "Slave ID: 1"
271072-271490 modbus: cs-function: "Function 6: Write Single Register"
271650-272645 modbus: cs-address: "Address 0x1 / 30001"
272804-273800 modbus: cs-data: "Register Value 0x55 / 85"
273959-274954 modbus: cs-crc: "CRC correct"
277202-277620 modbus: sc-server-id: "Slave ID: 1"
277776-278194 modbus: sc-function: "Function 6: Write Single Register"
278350-279342 modbus: sc-address: "Address 0x1 / 30001"
279497-280489 modbus: sc-data: "Register Value 0x55 / 85"
280645-281637 modbus: sc-crc: "CRC correct"
285449-285867 modbus: cs-server-id: "Slave ID: 1"
286026-286444 modbus: cs-function: "Function 15: Write Multiple Coils"
286603-287599 modbus: cs-address: "Start at address 0x2 / 10003"
287758-288753 modbus: cs-length: "Write 1 Coils"
288913-289331 modbus: cs-length: "Byte count: 1"
289490-289908 modbus: cs-data: "Value 0x1"
290067-291063 modbus: cs-crc: "CRC correct"
293319-293737 modbus: sc-server-id: "Slave ID: 1"
293893-294311 modbus: sc-function: "Function 15: Write Multiple Coils"
294467-295458 modbus: sc-address: "Start at address 0x2 / 10003"
295614-296606 modbus: sc-data: "Write 1 Coils"
296762-297753 modbus: sc-crc: "CRC correct"