Age | Commit message (Collapse) | Author |
|
Data byte transmission is complete when the STOP bit was communicated.
End the STOP bit at the rising CLOCK edge of the 11th bit time, do not
rely on the host's clock inhibit after data transmission. This avoids
the unexpected expansion of a STOP bit well into the next data byte.
This fixes bug #1460, where absence of host activity after the first
data byte loses synchronization to the input stream.
Rephrase pin level sampling while we are here. Reflect that the clock
line is used for .wait() conditions, but its level is not evaluated.
Only data line levels get processed.
Comment on the implementation's assumption of specific input data (the
device as transmitter, host transmit may not be supported, or can result
in unexpected output). Which may be acceptable yet maintainers need to
remain aware.
|
|
This is managed by the backend and should be read-only for PDs.
|
|
Only add items to 'outputs' if the respective PD actually has
OUTPUT_PYTHON support implemented as of right now.
Various decoders might get OUTPUT_PYTHON support later, but the
'outputs' field should reflect the current status.
|
|
|
|
|
|
Move initialization code of protocol decoders from the constructor to a
new reset() helper method. The libsigrokdecode backend could run this
method several times to clear the decoder's internal state, before new
data from another acquisition gets fed to decode() calls.
|
|
|
|
Remove the FSF postal address as it might change (it did in the past).
Reference the gnu.org website instead which is more stable.
|
|
|
|
|
|
|