summaryrefslogtreecommitdiff
path: root/decoders/lm75
AgeCommit message (Collapse)Author
2013-04-23GPL headers: Use correct project name.Uwe Hermann
2013-01-13Cosmetics, fix typos.Uwe Hermann
2012-11-24All PDs: Name the files pd.py consistently.Uwe Hermann
The Python module name is determined by the directory name (e.g. dcf77), the *.py file names in that directory don't matter and can be kept consistent.
2012-07-28srd: lm75: s/degrees Kelvin/Kelvin/.Uwe Hermann
The temperature unit is nowadays called just "Kelvin", not "degrees Kelvin" (even though this was not always the case).
2012-07-06srd: lm75: Output min/max/avg temperature in report().Uwe Hermann
This is just a preparation for later, the report() is not hooked up anywhere, yet.
2012-07-06srd: lm75: Warn about temperature reg. being read-only.Uwe Hermann
2012-07-06srd: lm75: Generic handling of register reads/writes.Uwe Hermann
2012-06-28srd: Add National LM75 protocol decoder.Uwe Hermann
This shall support the original National LM75 I2C-based temperature sensor, as well as various compatible devices of other vendors, such as the Fairchild FM75, Dallas DS75, and so on. Currently only 9bit resolution is supported, and not all commands are decoded, yet. The register contents and temperatures are decoded correctly though, and can be output in both Celsius and Kelvin.